Wholesale China Dissolved Oxygen Temperature Meter Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU Detail:
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle |
With platinum (Pt) as cathode and Ag / AgCl as anode |
The electrolyte is 0.1 M potassium chloride (KCI). |
The silicone rubber permeable membrane imported from U.S. serves as the permeable |
membrane. |
It has silicone rubber and steel gauze. |
It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape |
retention and other performances |
Measuring range: 0-100ug/L 0-20mg/L |
Electrode material: 316L stainless steel |
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
Sensor life: >3 years |
Cable length: 5m (double shielded) |
Detection lower Limit: 0.1ug/L(ppb)(20℃) |
Measurement upper limit: 20mg/l(ppm) |
Response time: ≤3min(90%, 20℃) |
Polarization time: >8h |
Minimum flow rate: 5cm/s; 515 L/h |
Drift: <3%/month |
Measurement error: <±1 ppb |
Air current: 50-80nA Note: Maximum current 20-25 uA |
Polarization voltage: 0.7V |
Zero Oxygen: <5ppb(60min) |
Calibration intervals: >60 days |
Measured water temperature:0~60℃ |
Measuring range: 0-100ug/L 0-20mg/L |
Electrode material: 316L stainless steel |
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
Sensor life: >3 years |
Cable length: 5m (double shielded) |
Detection lower Limit: 0.1ug/L(ppb)(20℃) |
Measurement upper limit: 20mg/l(ppm) |
Response time: ≤3min(90%, 20℃) |
Polarization time: >8h |
Minimum flow rate: 5cm/s; 515 L/h |
Drift: <3%/month |
Measurement error: <±1 ppb |
Air current: 50-80nA Note: Maximum current 20-25 uA |
Polarization voltage: 0.7V |
Zero Oxygen: <5ppb(60min) |
Calibration intervals: >60 days |
Measured water temperature:0~60℃ |
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Product detail pictures:

Related Product Guide:
We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for Wholesale China Dissolved Oxygen Temperature Meter Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU , The product will supply to all over the world, such as: Bangladesh, Jeddah, United Kingdom, They're durable modeling and promoting effectively all over the world. Under no circumstances disappearing major functions in a quick time, it's a should for you of excellent good quality. Guided by the principle of "Prudence, Efficiency, Union and Innovation. the company make a terrific efforts to expand its international trade, raise its company profit and raise its export scale. We're confident that we are going to possess a vibrant prospect and to be distributed all over the world within the years to come.