TSG-2087S Industrial Total Suspended Solids (TSS) Meter

Short Description:

TSG-2087S Industrial Total Suspended Solids (TSS) Meter can be used to display data measured by the sensor, so the user can get the 4-20mA analog output by transmitter’s interface configuration and calibration. And it can make relay control, digital communications, and other functions a reality. The product is widely used in sewage plant, water plant, water station, surface water, farming, industry and other fields.


  • facebook
  • linkedin
  • sns02
  • sns04

Product Detail

Technical Indexes

What Total Suspended Solids (TSS)?

The transmitter can be used to display data measured by the sensor, so the user can get the 4-20mA analog output by transmitter’s interface configuration and calibration. And it can make relay control, digital communications, and other functions a reality. The product is widely used in sewage plant, water plant, water station, surface water, farming, industry and other fields.


  • Previous:
  • Next:

  • Measuring range

    0~1000mg/L, 0~99999 mg/L, 99.99~120.0 g/L

    Accuracy

    ±2%

    Size

    144*144*104mm  L*W*H

    Weight

    0.9kg

    Shell Material

    ABS

    Operation Temperature 0 to 100℃
    Power Supply 90 – 260V AC 50/60Hz
    Output 4-20mA
    Relay 5A/250V AC  5A/30V DC
    Digital Communication MODBUS RS485 communication function, which can transmit real-time measurements
    Waterproof Rate IP65

    Warranty Period

    1 year

    Total suspended solids, as a measurement of mass are reported in milligrams of solids per liter of water (mg/L) 18. Suspended sediment is also measured in mg/L 36. The most accurate method of determining TSS is by filtering and weighing a water sample 44. This is often time consuming and difficult to measure accurately due to the precision required and the potential for error due to the fiber filter 44.

    Solids in water are either in true solution or suspended. Suspended solids remain in suspension because they are so small and light. Turbulence resulting from wind and wave action in impounded water, or the movement of flowing water helps maintain particles in suspension. When turbulence decreases, coarse solids quickly settle from water. Very small particles, however, may have colloidal properties, and can remain in suspension for long periods even in completely still water.

    The distinction between suspended and dissolved solids is somewhat arbitrary. For practical purposes, filtration of water through a glass fiber filter with openings of 2 μ is the conventional way of separating dissolved and suspended solids. Dissolved solids pass through the filter, while suspended solids remain on the filter.

  • Write your message here and send it to us