TPG-3030(1.0 Version) TP analyzer Liquiline System

Short Description:

The sample to be tested does not require any pretreatment. The water sample riser is directly inserted into the system water sample, and the total phosphorus concentration can be measured.

 

Feature

1.Separation of water and electricity, analyzer combined with filtering function.
2.Panasonic PLC, faster data processing, long-term stable operation
3.High temperature and high pressure resistant valves imported from Japan, operating normally

in harsh environments.
4.Digestion tube and measuring tube made by Quartz material to ensure high accuracy of water

samples.
5.Set the digestion time freely to meet customer’s special demand.


  • facebook
  • linkedin
  • sns02
  • sns04

Product Detail

Technical Indexes

The sample to be tested does not require any pretreatment. The water sample riser is directly inserted into the system water sample, and the total phosphorus concentration can be measured. The maximum measurement range of this equipment is 0.1~500mg/L TP. This method is mainly used for on-line automatic monitoring of total phosphorus concentration of waste (sewage) water discharge point source, surface water, etc.


  • Previous:
  • Next:

  • Methods National Standard GB11893-89 “Water quality – Determination of total phosphorus Ammonium molybdate spectrophotometric method”. TPG-3030
    Measuring range 0-500mg/L TP (0-2mg/L;0.1-10mg/L;0.5-50mg/L; 1-100mg/L;5-500mg/L)
    Accuracy no more than±10% or no more than±0.2mg/L
    Repeatability no more than ±5% or no more than ±0.2 mg/L
    Measurement period minimum measuring period of 30 min, according to actual water samples, can be modified at 5 ~ 120min arbitrary digestion time.
    Sampling period the time interval (10 ~ 9999min adjustable) and the whole point of measurement mode.
    Calibration period 1~99 days, any interval, any time adjustable.
    Maintenance period once a month, each about 30 min.
    Reagent for value-based management Less than 3 yuan/samples.
    Output RS-232;RS485;4~20mA three ways
    Environmental requirement temperature adjustable interior, it is recommended temperature 5~28℃;humidity≤90%(no condensing)
    Power supply AC230±10%V, 50±10%Hz, 5A
    Size 1570 x500 x450mm(H*W*D).
    Others abnormal alarm and power failure will not lose data;

    Touch screen display and command input
    Abnormal reset and power off after the call, the instrument automatically discharge the residual reactants inside the instrument, automatically return to work

  • Write your message here and send it to us