Online Integrated Turbidity Analyzer for drinking water

Short Description:

TBG-2088S/P turbidity analyzer can directly integrate the turbidity inside the whole machine, and centrally observe and

manage it on the touch screen panel display; the system integrates water quality online analysis, database and calibration

functions in one, Turbidity data collection and analysis provide great convenience.

1. Integrated system, can detect turbidity;

2. With original controller, it can output RS485 and 4-20mA signals;

3. Equipped with digital electrodes, plug and use, simple installation and maintenance;

4. Turbidity intelligent sewage discharge, without manual maintenance or reducing the frequency of manual maintenance;


  • facebook
  • linkedin
  • sns02
  • sns04

Product Detail

Technical Indexes

What Is Turbidity?

Turbidity Standard

Application field
Monitoring of chlorine disinfection treatment water such as swimming pool water, drinking water, pipe network and secondary water supply etc.


  • Previous:
  • Next:

  • Model

    TBG-2088S/P

    Measurement configuration

    Temp/turbidity

    Measuring range

    Temperature

    0-60℃

    turbidity

    0-20NTU

    Resolution and accuracy

    Temperature

    Resolution: 0.1℃   Accuracy: ±0.5℃

    turbidity

    Resolution: 0.01NTU  Accuracy: ±2% FS

    Communication Interface

    4-20mA /RS485

    Power supply

    AC 85-265V

    Water flow

    < 300mL/min

    Working Environment

    Temp: 0-50℃;

    Total power

    30W

    Inlet

    6mm

    Outlet

    16mm

    Cabinet size

    600mm×400mm×230mm(L×W×H)

    Turbidity, a measure of cloudiness in liquids, has been recognized as a simple and basic indicator of water quality. It has been used for monitoring drinking water, including that produced by filtration for decades. Turbidity measurement involves the use of a light beam, with defined characteristics, to determine the semi-quantitative presence of particulate material present in the water or other fluid sample. The light beam is referred to as the incident light beam. Material present in the water causes the incident light beam to scatter and this scattered light is detected and quantified relative to a traceable calibration standard. The higher the quantity of the particulate material contained in a sample, the greater the scattering of the incident light beam and the higher the resulting turbidity.

    Any particle within a sample that passes through a defined incident light source (often an incandescent lamp, light emitting diode (LED) or laser diode), can contribute to the overall turbidity in the sample. The goal of filtration is to eliminate particles from any given sample. When filtration systems are performing properly and monitored with a turbidimeter, turbidity of the effluent will be characterized by a low and stable measurement. Some turbidimeters become less effective on super-clean waters, where particle sizes and particle count levels are very low. For those turbidimeters that lack sensitivity at these low levels, turbidity changes that result from a filter breach can be so small that it becomes indistinguishable from the turbidity baseline noise of the instrument.

    This baseline noise has several sources including the inherent instrument noise (electronic noise), instrument stray light, sample noise, and noise in the light source itself. These interferences are additive and they become the primary source of false positive turbidity responses and can adversely impact the instrument detection limit.

    The subject of standards in turbidimetric measurement is complicated partly by the variety of types of standards in common use and acceptable for reporting purposes by organizations such as the USEPA and Standard Methods, and partly by the terminology or definition applied to them. In the 19th Edition of Standard Methods for the Examination of Water and Wastewater, clarification was made in defining primary versus secondary standards. Standard Methods define a primary standard as one that is prepared by the user from traceable raw materials, using precise methodologies and under controlled environmental conditions. In turbidity, Formazin is the only recognized true primary standard and all other standards are traced back to Formazin. Further, instrument algorithms and specifications for turbidimeters should be designed around this primary standard.

    Standard Methods now define secondary standards as those standards a manufacturer (or an independent testing organization) has certified to give instrument calibration results equivalent (within certain limits) to results obtained when an instrument is calibrated with user-prepared Formazin standards (primary standards). Various standards that are suitable for calibration are available, including commercial stock suspensions of 4,000 NTU Formazin, stabilized Formazin suspensions (StablCal™ Stabilized Formazin Standards, which is also referred to as StablCal Standards, StablCal Solutions, or StablCal), and commercial suspensions of microspheres of styrene divinylbenzene copolymer.

  • Write your message here and send it to us