LSGG-5090Pro type industrial online phosphate analyzer, dopts special air rabbling and optoelectronics examination technique, make chemical react quickly and measure accuracy outstanding, optoelectronics examination and chart text display. Adopt colorful liquid crystal display, with the prolific color, character, chart and curve etc.

Can be widely used in thermal power plants, chemical industry and other departments, timely and accurate phosphate content of the water is monitoring to ensure crew working safely, economic, especially for the scene environment.


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • facebook
  • linkedin
  • sns02
  • sns04

Product Detail

Technical Indexes

User Manual

1. 1 ~ 6 channels to for optional, cost savings.

2. High accuracy, fast response.

3. Regular automatic calibration, maintenance workload is small.

4. Color LCD real-time curve, convenient for analysis working condition.

5. Save a month of historical data, easy recall.

6. Monochromatic cold light source, long life, good stability.

7. Multiple-precision programmable current output, suitable for subsequent automatic dosing or data acquisition system.


  • Previous:
  • Next:

  • 1 Measuring principle: phosphorus molybdenum alum yellow photoelectric colorimetry
    2  Measuring range: 0 ~ 2000μg / L, 0 ~ 10mg / L optional
    3 Accuracy: ± 1% F.S
    4 Reproducibility: ± 1% F.S
    5 Stability: drift ≤ ± 1% F.S/24 hour
    6 Response time: initial response, four minutes, six minutes to reach at least 98%
    7 Sampling period: 3 minutes / Channel
    8 Watery conditions: Flow> 2 ml / sec. Temperature: 10 ~ 45 ℃ Pressure: 10kPa ~ 100kPa
    9 Ambient temperature: 5 ~ 45 ℃ (higher than 40 ℃, reduced accuracy)
    10 Environment humidity: <85% RH
    11 Reagent types: one kind
    12 Reagent consumption: about 3 liters / month
    13 Output signal: 0 ~ 22mA within range of any set, each channel isolation
    14 Alarm: buzzer, relay normally open contacts
    15 Power: 220V ± 10%, 50Hz ± 1% 50W Main features
    16 Dimensions: 720mm (height) × 460mm (width) × 300mm (depth)
    17 Hole size: 665mm × 405mm

    LSGG-5090Pro User Manual