Functions |
EC |
Resistivity |
Salinity |
TDS |
Measuring range |
0.00uS-2000mS |
0.00-20.00 MΩ-CM |
0.00-78.00 g/Kg |
0-133000 ppm |
Resolution |
0.01/0.1/1 |
0.01 |
0.01 |
1 |
Accuracy |
±1%F.S. |
±1%F.S. |
±1%F.S. |
±1%F.S. |
Temp. compensation |
Pt 1000/NTC30K |
|||
Temp. range |
-10.0 to +130.0℃ |
|||
Temp. compensation range |
-10.0 to +130.0℃ |
|||
Temp. resolution |
0.1℃ |
|||
Temp. accuracy |
±0.2℃ |
|||
Cell constant |
0.001 to 20.000 |
|||
Ambient temperature range |
0 to +70℃ |
|||
Storage temp. |
-20 to +70℃ |
|||
Display |
Back light, dot matrix |
|||
EC current output1 |
Isolated, 4 to 20mA output , max. load 500Ω |
|||
Temp. current output 2 |
Isolated, 4 to 20mA output , max. load 500Ω |
|||
Current output accuracy |
±0.05 mA |
|||
RS485 |
Mod bus RTU protocol |
|||
Baud rate |
9600/19200/38400 |
|||
Maximum relay contacts capacity |
5A/250VAC,5A/30VDC |
|||
Cleaning setting |
ON: 1 to 1000 seconds, OFF: 0.1 to 1000.0 hours |
|||
One multi function relay |
clean/period alarm/error alarm |
|||
Relay delay |
0-120 seconds |
|||
Data logging capacity |
500,000 |
|||
Language selection |
English/traditional Chinese/simplified Chinese |
|||
Waterproof grade |
IP65 |
|||
Power supply |
From 90 to 260 VAC, power consumption < 5 watts |
|||
Installation |
panel/wall/pipe installation |
|||
Weight |
0.85Kg |
Functions | EC | Resistivity | Salinity | TDS |
Measuring range | 0.00uS-2000mS | 0.00-20.00 MΩ-CM | 0.00-78.00 g/Kg | 0-133000 ppm |
Resolution | 0.01/0.1/1 | 0.01 | 0.01 | 1 |
Accuracy | ±1%F.S. | ±1%F.S. | ±1%F.S. | ±1%F.S. |
Temp. compensation | Pt 1000/NTC30K | |||
Temp. compensation range | -10.0 to +130.0℃ | |||
Temp. Resolution and accuracy | 0.1℃,±0.2℃ | |||
Storage temp. | -20 to +70℃ | |||
Display | Back light, dot matrix | |||
EC current output1 | Isolated, 4 to 20mA output , max. load 500Ω | |||
Temp. current output 2 | Isolated, 4 to 20mA output , max. load 500Ω | |||
RS485 | Mod bus RTU protocol | |||
Baud rate | 9600/19200/38400 | |||
Maximum relay contacts capacity | 5A/250VAC,5A/30VDC | |||
Cleaning setting | ON: 1 to 1000 seconds, OFF: 0.1 to 1000.0 hours | |||
One multi function relay | clean/period alarm/error alarm | |||
Relay delay | 0-120 seconds | |||
Data logging capacity | 500,000 |
Conductivity is a measure of water’s capability to pass electrical flow. This ability is directly related to the concentration of ions in the water
1. These conductive ions come from dissolved salts and inorganic materials such as alkalis, chlorides, sulfides and carbonate compounds
2. Compounds that dissolve into ions are also known as electrolytes 40. The more ions that are present, the higher the conductivity of water. Likewise, the fewer ions that are in the water, the less conductive it is. Distilled or deionized water can act as an insulator due to its very low (if not negligible) conductivity value 2. Sea water, on the other hand, has a very high conductivity.
Ions conduct electricity due to their positive and negative charges
When electrolytes dissolve in water, they split into positively charged (cation) and negatively charged (anion) particles. As the dissolved substances split in water, the concentrations of each positive and negative charge remain equal. This means that even though the conductivity of water increases with added ions, it remains electrically neutral 2