BH-485-ORP Digital ORP Sensor

Short Description:

★ Measure range: -2000mv~+2000mv
★ Protocol:  Modbus RTU RS485
★ Features: rapid response, strong anti-interference ability
★ Application: waste water, river water, swimming pool


  • facebook
  • linkedin
  • sns02
  • sns04

Product Detail

Technical Indexes

What is ORP?

Manual

BH-485 Series of online ORP electrode, adopt electrode measuring method, and realizes the automatic temperature compensation in the interior of the electrodes, Automatic identification of standard solution. Electrode adopt imported composite electrode, high precision, good stability,long lifetime, with rapid response, low maintenance cost, real-time online measurement characters etc.. The electrode using standard Modbus RTU (485) communication protocol, 24V DC power supply, four wire mode can very convenient access to sensor networks.


  • Previous:
  • Next:

  • Model BH-485-ORP
    Parameter measurement ORP, Temperature
    Measure range mV: -1999~+1999  Temperature: (0~50.0)℃
    Accuracy mV: ±1 mV   Temperature: ±0.5℃
    Resolution mV: 1 mV   Temperature: 0.1℃
    Power supply 24V DC
    Power dissipation 1W
    Communication mode RS485(Modbus RTU)
    Cable length 5 meters, can be ODM depend on user’s requirements
    Installation Sinking type, pipeline, circulation type etc.
    Overall size 230mm×30mm
    Housing material ABS

    Oxidation Reduction Potential (ORP or Redox Potential) measures an aqueous system’s capacity to either release or accept electrons from chemical reactions. When a system tends to accept electrons, it is an oxidizing system. When it tends to release electrons, it is a reducing system. A system’s reduction potential may change upon introduction of a new species or when the concentration of an existing species changes.

    ORP values are used much like pH values to determine water quality. Just as pH values indicate a system’s relative state for receiving or donating hydrogen ions, ORP values characterize a system’s relative state for gaining or losing electrons. ORP values are affected by all oxidizing and reducing agents, not just acids and bases that influence pH measurement.

    From a water treatment perspective, ORP measurements are often used to control disinfection with chlorine or chlorine dioxide in cooling towers, swimming pools, potable water supplies, and other water treatment applications. For example, studies have shown that the life span of bacteria in water is strongly dependent on the ORP value. In wastewater, ORP measurement is used frequently to control treatment processes that employ biological treatment solutions for removing contaminants.

    BH-485-ORP Digital ORP Sensor User manual